91685
DC-788
Counting Scale
Operation Manual
Counting Scale
Version 1.09
Vista de pagina 0
1 2 3 4 5 6 ... 60 61

Indice de contenidos

Pagina 1 - Operation Manual

91685DC-788 Counting ScaleOperation ManualCounting ScaleVersion 1.09

Pagina 2

6 DC-788 Operation Manual2.0 InstallationThis section describes the procedure for the installation and setup of the DC-788 counting scale.2.1 Unpackin

Pagina 3 - Contents

Installation 72.2 RepackingIf the DC-788 counting scale must be returned for modification, calibration or repair, it must be properly packed with suff

Pagina 4 - Version 1.09, July 2007

8 DC-788 Operation Manualdisplay’s segments. How thorough the segment check is depends on the setting of SPC 20, Bit 2. The default is 1: Normal (Fo

Pagina 5 - 1.0 Introduction

Installation 96. Attach the red lead to the positive (+) terminal of the new DC battery pack, and the black lead to the negative (-) terminal. Place

Pagina 6 - 1.3 Keyboard and Display

10 DC-788 Operation Manual2.5 Setting the DateWithout a power supply, the DC-788 will reset the time and date. For units that do have battery power, t

Pagina 7

Installation 112.7 Block Diagram of Electrical ConnectionsThe following block diagram illustrates the electrical connections.2.8 Physical Layout of El

Pagina 8

12 DC-788 Operation Manual3.0 Configuration SettingsThis section presents the setup and configuration of the DC-788 counting scale to be used specific

Pagina 9

Configuration Settings 13SPEC No. Bit 3 Bit 2 Bit 1 Bit 000 Auto Power-off Function (for no key operation and weighing operation)0000: Auto power-off

Pagina 10 - 2.0 Installation

14 DC-788 Operation Manual08 RS-232C PC Protocol0000: Inhibit data transfer (DEFAULT)0001: Standard stream type (continuous output0010: Standard manua

Pagina 11 - 2.4 Powering Up the DC-788

Configuration Settings 153.1.2 Weight and Measurement Specifications (142 Settings)To make changes to the Weight and Measurement Specifications, the s

Pagina 13 - 2.4.4 Start-Up Screens

16 DC-788 Operation ManualSPEC No. Bit 3 Bit 2 Bit 1 Bit 020 Version Display When Power On0: Allow (DEFAULT)1: Inhibit (SP_VER)Selection of Segment-

Pagina 14 - 2.5 Setting the Date

Configuration Settings 1726 Weight Stability Conditions00: Loose01: Normal (DEFAULT)10: Tight11: Stringent(SPWTATABC)2nd ScalePlease note that the sca

Pagina 15 - Installation 11

18 DC-788 Operation Manual32 Exit From Accumulation Mode After 15 Second Time Out0: Allow (DEFAULT)1: Inhibit(SP_EA15)Exit From Acculumation Mode When

Pagina 16 - 3.0 Configuration Settings

Calibration 194.0 CalibrationThe DC-788 counting scale is a high-precision instrument. Although the scale needs very little maintenance, you may want

Pagina 17

20 DC-788 Operation Manual4. The scale display will confirm that you are in the Calibration Mode. 5. You can select which scale you are calibrating, S

Pagina 18

Scale Operations 215.0 Scale OperationsThe following sections contain detailed operator instructions for the DC-530 counting scale (see Figure 5-1). I

Pagina 19

22 DC-788 Operation Manual5.2 Weight Unit SwitchingThe weight units displayed can be changed between Kg and Lb during weighing operations by pressing

Pagina 20

Scale Operations 232. Place another tare weight on the platform and press the TARE key again. This will add the two tare weights together (Tare Additi

Pagina 21

24 DC-788 Operation ManualIf the sample size is insufficient to give an accurate unit weight, no unit weight will be displayed, the INSUFF lamp will b

Pagina 22

Scale Operations 251. At the stand-by screen, press the MODE key twice to enter the Programming Mode.2. Press and hold the REZERO key while entering [

Pagina 23 - 4.0 Calibration

Contents1.0 Introduction...

Pagina 24 - 20 DC-788 Operation Manual

26 DC-788 Operation Manual5. Remove container 1 and place container 2 (full of parts) on the scale.6. Press the + (Plus) key (Total 2 is equal to cont

Pagina 25 - 5.0 Scale Operations

Scale Operations 275.8.2.4 Counting Out of a Full Container - See Total Amount Remaining in the ContainerTo carry out this operation you must know the

Pagina 26 - 5.3 Toggling Between Scales

28 DC-788 Operation Manual5.8.3.9 Change the Part Name Temporarily1. In the Weighing Mode, enter a “3” as a command code from the keypad, then press t

Pagina 27 - 5.5 Entering Unit Weights

Scale Operations 292. When an Item Code is recalled from memory, the Inventory indicator will start out pointing to OUT, meaning that inventory quanti

Pagina 28 - 5.7 Setting a Sequence Number

30 DC-788 Operation Manualindicators will no longer be illuminated. (Note: If you try to press the CLEAR key while there is data in the accumulation

Pagina 29

Scale Programming 316.0 Scale ProgrammingThe DC-788 can store information for the parts you count most frequently, eliminating the need for re-enterin

Pagina 30 - 5.8.2.3 Negative Counting

32 DC-788 Operation Manual6.2 Review the Item Code Numbers Programmed in MemoryTo see what Item Codes are currently programmed in the DC-788’s memory,

Pagina 31 - Scale Operations 27

Scale Programming 33display will show the field that the data is being entered for. Once the display of this character clears, the scale is ready to a

Pagina 32 - 5.9.2 View Item Information

34 DC-788 Operation Manual02: SET POINT ALARM must be set to “0: ON”. See Section 3.1.1 for instructions on how to set Customer specifications.). He

Pagina 33 - Scale Operations 29

Scale Programming 35•There are four types of setpoints which can be selected by setting SPC 04, Bits 1 and 0: % of Quantity (%QTY), % of Weight (%WT),

Pagina 34 - 5.9.5 Delete Item Memory

6.0 Scale Programming... 316.1 Checki

Pagina 35 - 6.0 Scale Programming

36 DC-788 Operation Manual6.7.1 Change the Lot Number Temporarily1. In the Weighing Mode, enter a “1” as a command code from the keypad, then press th

Pagina 36

Scale Programming 37If you have entered an existing Item Code, the display will ask you to confirm that you want to delete. Press the CLEAR key to del

Pagina 37

38 DC-788 Operation Manualdelete. 4. Press the CLEAR key to delete all unit weights in memory, or press the MODE key to cancel the deletion. If you p

Pagina 38 - Table 6-4. Setpoint Examples

Scale Programming 39delete. 4. Press the CLEAR key to delete all part numbers in memory, or press the MODE key to cancel the deletion. If you pressed

Pagina 39 - Table 6-6. Setpoint Examples

40 DC-788 Operation Manualdelete. 4. Press the CLEAR key to delete all part names in memory, or press the MODE key to cancel the deletion. If you pres

Pagina 40 - 6.8 Delete Item Memory

External Devices: Printers, PCs and Scales 417.0 External Devices: Printers, PCs and ScalesThe DC-788 Counting Scale is equipped with an RS-232C port

Pagina 41 - Scale Programming 37

42 DC-788 Operation Manual7.1.3 Epson TM-U210 and TM-U290, Star SP2320 and SP2987.2 Printer Label FormatsSPC09 - External Printer Type sets the type o

Pagina 42 - 38 DC-788 Operation Manual

External Devices: Printers, PCs and Scales 43Figure 7-2. Zebra Default Total Label SampleFigure 7-3. Zebra Default Label When Not Recalling Item Code

Pagina 43 - Scale Programming 39

44 DC-788 Operation Manual7.2.4 Epson TMU200 or Star SP2320 Tape PrinterSet SPC09 to 0011. These two tape printers use a default format which is down

Pagina 44 - Programming Mode screen

External Devices: Printers, PCs and Scales 457.3 Connecting to a PC7.3.1 Setting the Scale Specifications for Communication to a PCThe DC-788’s RS-232

Pagina 45 - 7.1 Printer Connection

Introduction 1About This ManualThis manual contains operating procedures for the DC-788 counting scale and provides the user with all the information

Pagina 46 - 7.2 Printer Label Formats

46 DC-788 Operation Manual7.3.2.7 Standard Manual Data TransmissionSet SPC08-RS232C PC Protocol to 0010: Standard Manual Type. The communication betw

Pagina 47 - Table 7-1. Output Data Order

External Devices: Printers, PCs and Scales 477.3.2.9 Standard Command Data TransmissionSet SPC08-RS232C PC Protocol to 0011: Standard Command Type. T

Pagina 48 - 44 DC-788 Operation Manual

48 DC-788 Operation Manual7.3.3 Pin AssignmentsThe DC-788 counting scale is connected to a PC using a 9 pin D-SUB connectors configured as follows:If

Pagina 49 - 7.3 Connecting to a PC

External Devices: Printers, PCs and Scales 497.3.5 RS-232C Data Transmission FormatsThe basic data transmission string format output by the DC-788 is

Pagina 50 - 46 DC-788 Operation Manual

50 DC-788 Operation ManualData about an ID Code is only transmitted if an ID Code has been recalled from the scale’s memory. The data transmitted (if

Pagina 51

External Devices: Printers, PCs and Scales 51By ASCII Code: Example 2:If the same parameters are true as above but with a weight overflowThe data tran

Pagina 52 - 7.3.3 Pin Assignments

52 DC-788 Operation Manual7.4.1 Setting the Specifications for Scale 2A scale connected to the Remote Scale Channel will be recognized by the DC-788 a

Pagina 53

External Devices: Printers, PCs and Scales 537.4.2 Remote Platforms AvailablePlatform Capacity Platform Dimensions100.00 lbs 13" x 17" (DIG

Pagina 54 - 0 1 0 0 0 0 1 0

54 DC-788 Operation Manual8.0 Appendix8.1 DC-788 SpecificationsOperating Conditions• Power Source - AC117/100V• Operating Temperature- -10°C ~ +40°C (

Pagina 55 - 7.4 Remote Scale Channel

Appendix 558.3 ASCII Code Table 8 8 8 8 8 8 Happens when the scale is not stable when the power is on. If a second scale is enabling, it must also be

Pagina 56

2 DC-788 Operation Manual1.2 Modes of Operation1.2.1 Description of Modes of OperationThe DC-788 has three modes of operation:• Weighing Mode – where

Pagina 57

56 DC-788 Operation Manual54686V118v150–182¶214Ö246ö55787W119w151—183·215×247÷56888X120x152˜184¸216Ø248ø57989Y121y153™185¹217Ù249ù58:90Z122z154š186º21

Pagina 58 - 8.0 Appendix

DC-788 Limited Warranty 579.0 DC-788 Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed

Pagina 59 - 8.3 ASCII Code Table

Introduction 31.3.3 Key FunctionsThe DC-788 features many functions for managing inventory information and scale operation. Figure 1-2 shows the two k

Pagina 60 - 56 DC-788 Operation Manual

4 DC-788 Operation ManualCLEAR key.Weighing Mode - Used to clear the Unit Weight. Used to return to the weighing display when doing accumulation.Prog

Pagina 61 - 9.0 DC-788 Limited Warranty

Introduction 5KG/LB/INVENT key- Used to convert the weighing units between kg and lb. Also used to toggle on and off whether inventory stored in mem