XStream-PKG-R™ RS-232/485 RF Modem Product Manual v5.x00
Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up
initializer contains initialization information and all receiving modems must wake during the
wake-up initializer portion of data transmission in order to be synchronized with the transmitting
modem and receive the data.
Figure 3.7. Correct Configuration (LH > SM)
Length of the wake-up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect
the wake-up initializer and receive the accompanying payload data.
Figure 3.8. Incorrect Configuration (LH < SM)
Length of wake-up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable
to the receiver waking and missing the wake-up initializer (and therefore also the accompanying payload data).