9XCite™RS‐232/485RFModem–ProductManualv2.1[2007.01.04]
©2007MaxStream,Inc. 10
2.3. RS-485 (4-wire) & RS-422 Operation
2.3.1. DIP Switch Settings and Pin Signals
2.3.2. Wiring Diagrams
Figure2‐13. XCiteRFModeminanRS‐485(4‐wire)environment
Table2‐03. RS‐485/422(4‐wire)SignalsandtheirimplementationsontheXCiteRFModem
DB-9 Pin
RS-485/422
Name
Description Implementation
2T- (TA)
Transmit Negative
Data Line
Serial data sent from the RF modem
3R- (RA)
Receive Negative
Data Line
Serial data received by the RF modem
5 GND Signal Ground Ground
7 R+ (RB)
Receive Positive
Data Line
Serial data received by the RF modem
8T+ (TB)
Transmit Positive
Data Line
Serial data sent from the RF modem
9PWR Power
Optional power input that is connected internally
to the front power connector
1, 4, 6 not used
Figure2‐10.
RS‐485(2‐wire)Half‐duplex
DIPSwitchSettings
Figure2‐11.
PinsusedonthefemaleRS‐232(DB‐9)
SerialConnector
Figure2‐12.
RS‐485(2‐wire)w/Termination(optional)
Terminationisthe120ΩresistorbetweenT+andT‐.
DIPSwitchsettingsarereadandapplied
onlywhilepowering‐on.
Comentarios a estos manuales