Monitoring capabilities in the web interface
218
XBee network errors
This section includes error counts for all activity on the XBee network. These values help
determine the quality of data that is being sent or received.
Removed from queue
The number of frames that could not be transmitted due to a time limit set by an application.
Unable to transmit
The number of frames that could not be transmitted due to a transmission error. This includes
duty cycle limits and CCA and PHY errors.
Address not found
The number of transmitted frames for which the network address of a remote node could not
be found.
Route not found
The number of transmitted frames for which the route to a remote node could not be found.
Not acknowledged
The number of transmitted frames that were not acknowledged by the remote node.
No response or status
The number of transmitted frames for which no indication of success or failure was received
from the local radio.
XBee device status pages
Configuration > Network > XBee > Device Status displays detailed information on the state of
Digi device and its role as a gateway device in the XBee network. The parameters displayed vary
based on the capabilities supported by the node's XBee module. See "Device Status" on page 129.
Watchport Sensor statistics
To be provided.