Hardware installation for ConnectPort X4 H
39
Cable fittings
To route serial, Ethernet or sensor cables outside the enclosure, and maintain IP66 rating, the three
hole plugs can be replaced with cable fittings, available in different diameters. These cable fittings
can be purchased separately from Digi.
To wire sensors through cable fittings:
1 Locate cord grip to attach sensor. Different diameter cord grips are available for different
sensors, please contact Digi for purchase.
2 Wire sensor to the 14-pin connector plug using the pinout guide provided in the enclosure or
in the pinout section on page 34. Up to 4 sensors can be wired into the 14-pin connector.
Note
Make sure that all cable fittings are tightened and all empty holes are plugged before
use to maintain environmental rating.
Antenna options and connectors
ConnectPort X4 H has two antenna connectors, one for cellular networks and the other for XBee
networks. Connect the antennas that come with the unit you purchased.