Alerts and Notifications
Chapter 6 63
Traps
There are additional traps that can be set at the port level. The following table
shows where the trap is under Serial port > Configuration on the web
interface, trap name, configure options, and the trap functions. The MIBs for
login traps can be found at http://ftp.digi.com/support/utilities/digicm/
Configuring SNMP
To configure the Digi CM unit for SNMP do the following:
1. Access the Digi CM unit’s web interface.
2. Under the Network heading, choose SNMP configuration.
3. Fill in information for the MIB-II system objects section and choose Yes
under EnableAuthenTrap. The fields are described in the following section:
sysContact - Identity of the contact person managing the MIB-II system.
sysName - The name identifying the system. By convention, this is the fully
qualified domain name of the Digi CM unit. An example is:
sysLocation. - The physical location of the unit such as Room 264 or
Engineering Lab.
sysService (Read only). - A series of values, separated by commas,
indicating the set of services the system provides. By default, the Digi CM
unit only supports Application (7) service level.
EnablePowerOnTrap. - Determines whether the SNMP agent generates a
trap each time the Digi CM unit is started.
EnableAuthenTrap. - Indicates whether the SNMP agent process is permitted
to generate authentication failure traps.
TRAP Notifies a system administrator of a significant event
Protocol Function
Trap Location Trap Name Function
Port access menu Port login trap
Notify about any login action to the port access menu
(succeed and fail)
Alert configuration Port login trap
Notify about login to this specific port (succeed and fail)
(only available if host mode is set to "Console server")
Alert configuration Device connection trap
Notify about a change of the DTR signal line (only
available if host mode is set to "Console server")
Alert configuration Active detection trap
Notify about changes in the device's response to the
probe string (see also "Automatic Device Recognition" on
page 23, only available if host mode is set to "Console
server")
Alert configuration Dial-in modem test trap
Notify about modem test (succeed and fail) (only available
if host mode is set to "Dial-in modem")
Port event handling Keyword notification trap
Notify about the occurrence of a keyword in the port log
(only available if host mode is set to "Console server")