Management
AnywhereUSB Remote I/O Concentrator User Guide 48
using the Backup/Restore operation, which provides a means for restoring it after the
configuration issues have been resolved.
1. Make a backup copy of the configuration using the Backup/Restore operation.
2. From the Main menu, click Administration > Factory Default Settings. The Factory Default
settings page is displayed.
3. Check the Keep network settings checkbox to keep the current network settings such as the IP
address and host key settings. In addition, any files that were loaded into the device through
the File Management page such as custom-interface files and applet files are retained.
4. Click Restore.
Using the Boot Command
Refer to Chapter 10 for more information.
From the command line, the boot action=factory command clears all current configuration
settings, except the IP address settings, host key settings, and password for the administrative/
root user; restores the settings to the factory defaults; then reboots the device.
#> boot action=factory
There are several other options for using the boot command to load configuration settings. Enter
help boot to see all command options.
Using the front panel Reset button
If the AnywhereUSB cannot be accessed from the web interface, the configuration can be
restored to factory defaults using the Reset button. This kind of reset clears all configuration
settings.
1. Disconnect power from the AnywhereUSB.
2. Hold down the front panel Reset button.
3. While holding the Reset button down, connect power to the AnywhereUSB.
4. Wait about 10 seconds, until the System Status LED blinks a Red 1-5-1 code.
5. Release the Reset button.
Display system information
System information displays the model, MAC address, firmware version, boot version, and POST
version of the AnywhereUSB. It also displays memory statistics, CPU utilization, and how long the
unit has been running since the last power-on or reboot.