Management
AnywhereUSB Remote I/O Concentrator User Guide 50
Reboot the AnywhereUSB
Changes to some device settings require saving the changes and rebooting the AnywhereUSB.
To Reboot the Unit from the Web UI:
1. From the web interface menu, select Administration > Reboot.
2. On the Reboot page, click the Reboot button. Wait approximately 1 minute for the reboot to
complete.
To Reboot the Unit using the front panel reset button:
1. Hold down the front panel Reset button for about 2 seconds, until the front panel LEDs start
blinking an amber color.
2. Quickly release the Reset button then hold it down again.
3. Wait about 4 seconds, until the front panel LEDs flicker then turn off.
4. Release the Reset button.
Note: This reboot procedure is only applicable when the AnywhereUSB is in a normal operational
state, i.e. when the System Status LED is blinking green. If the System Status LED is blinking a
repeating Red code (instead of slow green), please contact Digi technical support.